Omicron CPC100 Substation Test Set Hire
- Title
- Omicron CPC100 Substation Test Set
- Make
- Omicron
- Model
- CPC100
- Weight Capacity
- Weight Capacity
- Number in Fleet
- 20
The Omicron CPC 100 is a powerful device which can perform testing on numerous substation components via an uncomplicated user friendly interface. It can provide up to 800 A or 2 kV on its own, or up to 2 kA or 12 kV with the use of amplifier modules, along with up to 5 kVA over a frequency range of 15 to 400 Hz or 400 A DC. The CPC 100 features a variable output which allows the use of test frequencies different from the mains frequency offering a very effective suppression of mains-related interference for use in noisy environments. The CPC 100 can also test unconventional current transformers and integrated IEC 61850 systems via the use of sampled values, commission protection relay systems, analyze power lines and HV cables, perform grounding systems tests and when combined with additional modules perform tests on rotating machines, switchgear and circuit breakers and GIS systems.
Current transformer testing
CT ratio (with burden)
CT burden
CT excitation curve (knee point)
Polarity check with CPOL
Accuracy limiting factor (ALF) test
CT ratio with voltage
CT winding resistance
CT voltage withstand test
CT ratio Rogowski and CT ratio low power
Power / dissipation factor (tan δ) test
IEC 61850 Sampled Values testing
Voltage transformer testing
VT ratio
VT burden
VT secondary voltage withstand test
Polarity check with CPOL
VT electronics
IEC 61850 Sampled Values testing
Power / dissipation factor (tan δ) test
Power transformer testing
DC winding resistance
Dynamic load tap changer diagnostics
Transformer turns ratio (TTR) per tap
Leakage reactance / short circuit impedance
Bushing: power / dissipation factor (tan δ) + insulation capacitance
Transformer: power / dissipation factor (tan δ) + insulation capacitance
Insulating fluids: power / dissipation factor (tan δ)
Excitation current per tap
Frequency response of stray losses (FRSL)
Surge arrestors: leakage current and watt losses
Cable and transmission line diagnosis
Line impedance and k-factor
Mutual coupling
Positive or zero sequence impedance
Ground system analysis
Ground grid impedance for large systems
Step and touch voltage
Ground grid impedance for small systems
Soil resistivity
Integrity check of grounding connection
Reduction factor / current split factor
Measure multiple current paths with Rogowski coil
Switchgear / circuit breaker testing
Contact resistance
Bushing: power / dissipation factor (tan δ) + insulation capacitance
Overcurrent relays with primary injection (MV)
Circuit breaker: Power / dissipation factor (tan δ)
Insulating fluids: power / dissipation factor (tan δ)
Rotating machines diagnosis
Power / dissipation factor (tan δ) tip-up test at 50 / 60 Hz
Power / dissipation factor test with variable frequency
HV source for testing rotating machines
GIS testing
Withstand test
Protection installation testing
CT ratio (with burden)
CT burden
CT excitation curve (knee point)
VT ratio
VT burden
Overcurrent relays with primary injection (MV)
Polarity check with CPOL
Testing of the entire protection chain
Sampled Values testing
SV CT ratio test and polarity check
SV VT ratio test and polarity check
Automatic MU detection
Automatic voltage / current channel detection
Frequency selective voltage / current meter
Noise level measurement
Amplitude response of the signal processing chain
Precise Facilities - Osborne Park, WA
- Address
- OSBORNE PARK, WA, 6017
- Website
- http://www.precisefacilities.com.au